Electrical defects in new builds
Electrical snags range from a socket that isn’t level to missing RCD protection or exposed wiring. A plug-in socket tester checks the outlets quickly, while anything beyond a visual check is work for an electrician.
Updated 19 October 2026
SiteSnag’s library has 28 entries under electrical, and 8 of them are marked as safety or critical items. They’re listed below with the most serious first. Each one gives the wording an inspector would put in a report and the trade that would fix it, and 20 carry a reference to the standard or guidance they relate to. The references help you look up the relevant section and aren’t a statement that a particular home does or doesn’t comply.
All 28 entries
Smoke alarm not working
SafetySmoke/heat alarm does not respond to test. Repair or replace immediately.
- Trade
- Electrician
- Reference
- Approved Document B
Exposed wiring
SafetyLive wiring or terminals exposed. Make safe immediately.
- Trade
- Electrician
- Reference
- BS 7671
No RCD protection / RCD trips
SafetyRCD protection absent or trips repeatedly. Investigate and rectify.
- Trade
- Electrician
- Reference
- BS 7671
Faceplate loose / missing
SafetySocket or switch faceplate loose or missing, exposing terminals. Fix immediately.
- Trade
- Electrician
- Reference
- BS 7671
Carbon monoxide alarm missing
SafetyCO alarm not fitted in room with a fixed combustion appliance. Fit alarm.
- Trade
- Electrician
- Reference
- Approved Document J
Smoke alarms not interlinked
SafetySmoke and heat alarms do not sound together. Interlink.
- Trade
- Electrician
- Reference
- BS 5839-6
Heat alarm missing in kitchen
SafetyNo heat alarm in the kitchen. Fit.
- Trade
- Electrician
- Reference
- BS 5839-6
Earth bonding missing
SafetyMain or supplementary bonding missing or not labelled. Install and test.
- Trade
- Electrician
- Reference
- BS 7671
Socket not working
MajorSocket outlet has no power. Investigate and repair.
- Trade
- Electrician
- Reference
- NHBC Standards 8.1
Outdated wiring / consumer unit
MajorWiring or consumer unit is old and needs an EICR. Recommend inspection.
- Trade
- Electrician
- Reference
- BS 7671
Light fitting not working
ModerateLight does not operate. Investigate and repair.
- Trade
- Electrician
- Reference
- NHBC Standards 8.1
Extractor fan not working
ModerateExtractor fan does not operate/run on. Repair or replace.
- Trade
- Electrician
- Reference
- NHBC Standards 8.1
EV charger not working
ModerateEV charge point not operating or not commissioned. Commission and provide certificate.
- Trade
- Electrician
- Reference
- BS 7671
Electrical certificate missing
ModerateElectrical installation certificate not provided. Provide certificate.
- Trade
- Electrician
- Reference
- BS 7671
External socket not working / no cover
ModerateOutside socket not working or weather cover missing. Repair.
- Trade
- Electrician
- Reference
- BS 7671
Downlight loose / not fire rated
ModerateDownlight drops from ceiling or is not fire rated where needed. Re-fix or replace.
- Trade
- Electrician
- Reference
- BS 7671
Sockets too close to sink / hob
ModerateSocket outlet within 300 mm of sink or hob. Relocate.
- Trade
- Electrician
- Reference
- BS 7671
Solar PV not working
ModerateSolar PV inverter shows a fault or not generating. Investigate.
- Trade
- Electrician
- Reference
- None listed
Socket or switch not level
MinorAccessory not level/flush with wall. Re-fix.
- Trade
- Electrician
- Reference
- NHBC Standards 8.1
Consumer unit not labelled
MinorCircuits not labelled at consumer unit. Label all circuits.
- Trade
- Electrician
- Reference
- BS 7671
Light fitting loose / not level
MinorLight fitting loose or not aligned. Re-fix.
- Trade
- Electrician
- Reference
- None listed
External light / PIR not working
MinorExternal light or sensor not working. Repair.
- Trade
- Electrician
- Reference
- None listed
TV / data point not working
MinorTV, satellite or data outlet not working. Test and repair.
- Trade
- Electrician
- Reference
- None listed
Doorbell not working
MinorDoorbell or chime not working. Repair.
- Trade
- Electrician
- Reference
- None listed
Switch controls wrong light
MinorSwitch operates the wrong light or two-way switching not working. Correct wiring.
- Trade
- Electrician
- Reference
- BS 7671
Dimmer flickering / buzzing
MinorLights flicker or dimmer buzzes. Fit compatible dimmer or lamps.
- Trade
- Electrician
- Reference
- None listed
Loft light / socket missing
MinorNo light or power in the loft where specified. Provide.
- Trade
- Electrician
- Reference
- None listed
Meter box damaged
MinorGas or electric meter box damaged or door missing. Replace.
- Trade
- Builder
- Reference
- None listed
Using these in a report
In the SiteSnag app, starting to type a defect title in the camera brings up these entries. Picking one fills in the description, severity, trade and reference, and you can edit the wording or add your own defects to the library. Every snag then goes into the branded PDF report with its photos and a numbered pin on the floor plan.
For a room-by-room walk-round, use the new build snagging checklist, or go back to all defect categories.
Other categories
Previous: Heating (15). Next: External (33).
- Decoration (20)
- Walls & ceilings (19)
- Doors & joinery (38)
- Windows & glazing (22)
- Floors (16)
- Tiling (12)
- Kitchen (42)
- Bathroom (29)
- Plumbing (17)
- Heating (15)
- External (33)
- General (9)
- Ventilation (6)
- Insulation & damp (10)
- Roofing (18)
- Drainage (8)
- Garage (5)
- Fire safety (17)
- Accessibility (8)
- Commercial fit-out (10)
- Mechanical & electrical (11)
- Lifts & doors (5)
- Car park & external works (7)
- Signage & security (6)
- Fitted furniture (7)
- Stairs (6)
- Structure (8)
- Timber & pests (8)
- Communal areas (6)