Windows & glazing defects in new builds
Every window should open, close and lock, and the ones on upper floors need restrictors. A torch held against the glass shows up scratches and misted units that are easy to miss in daylight.
Updated 19 October 2026
SiteSnag’s library has 22 entries under windows & glazing, and 3 of them are marked as safety or critical items. They’re listed below with the most serious first. Each one gives the wording an inspector would put in a report and the trade that would fix it, and 15 carry a reference to the standard or guidance they relate to. The references help you look up the relevant section and aren’t a statement that a particular home does or doesn’t comply.
All 22 entries
Window restrictor missing
SafetyWindow restrictor missing or not working. Fit/adjust restrictor.
- Trade
- Glazier
- Reference
- Approved Document K
Escape window does not open fully
SafetyEmergency escape window does not open to the required clear opening. Adjust hinges/restrictor.
- Trade
- Glazier
- Reference
- Approved Document B
Glazing in critical location not safety glass
SafetyGlazing in a critical location (low level or near doors) has no safety marking. Confirm or replace with safety glass.
- Trade
- Glazier
- Reference
- Approved Document K
Roof window leaking
MajorRoof window or rooflight leaking at flashing or frame. Re-flash and seal.
- Trade
- Roofer
- Reference
- NHBC Standards 7.2
Scratched glazing
ModerateScratches to glass visible at normal viewing distance. Replace glazed unit.
- Trade
- Glazier
- Reference
- NHBC Standards 6.7
Missing / poor mastic seal
ModerateExternal mastic seal around frame missing or incomplete. Seal to prevent water ingress.
- Trade
- Glazier
- Reference
- NHBC Standards 6.7
Misted / blown double-glazed unit
ModerateCondensation between panes indicates a failed seal. Replace unit.
- Trade
- Glazier
- Reference
- NHBC Standards 6.7
Trickle vent missing / not working
ModerateTrickle vent missing, blocked or does not open. Fit or repair.
- Trade
- Glazier
- Reference
- Approved Document F
Window does not lock
ModerateWindow lock does not engage or key missing. Adjust or replace mechanism.
- Trade
- Glazier
- Reference
- Approved Document Q
Window not sealing / draughty
ModerateWindow lets in draughts at seals when closed. Adjust and replace seals.
- Trade
- Window installer
- Reference
- NHBC Standards 6.7
External sill damaged / no drip
ModerateExternal sill cracked, damaged or missing a drip. Repair or replace.
- Trade
- Builder
- Reference
- NHBC Standards 6.1
Rotten window frame / sill
ModerateTimber window frame or sill shows wet rot. Cut out and repair or replace.
- Trade
- Carpenter / Joiner
- Reference
- None listed
Window difficult to open/close
MinorWindow sash is stiff/does not close correctly. Adjust hinges and keeps.
- Trade
- Glazier
- Reference
- NHBC Standards 6.7
Window handle loose / missing
MinorWindow handle loose or missing. Fit/secure.
- Trade
- Glazier
- Reference
- None listed
Window board damaged / not sealed
MinorWindow board chipped or not sealed to frame. Repair and seal.
- Trade
- Carpenter / Joiner
- Reference
- None listed
Frame scratched / damaged
MinorWindow or door frame scratched or damaged. Repair or replace section.
- Trade
- Glazier
- Reference
- None listed
Window drops / hinges worn
MinorOpening casement drops or hinges are worn. Adjust or replace hinges.
- Trade
- Window installer
- Reference
- NHBC Standards 6.7
Window keys missing
MinorWindow lock keys not provided. Provide.
- Trade
- Developer
- Reference
- None listed
Drainage slots blocked / missing
MinorFrame drainage slots blocked or caps missing. Clear and fit.
- Trade
- Window installer
- Reference
- NHBC Standards 6.7
Sash window cords broken / stiff
MinorSash cords broken or sashes stiff. Re-cord and ease.
- Trade
- Carpenter / Joiner
- Reference
- None listed
Window beads loose / missing
MinorGlazing beads loose or missing. Re-fix.
- Trade
- Window installer
- Reference
- NHBC Standards 6.7
Blinds / curtain poles loose
MinorBlinds or curtain poles loose or not working. Re-fix.
- Trade
- Carpenter / Joiner
- Reference
- None listed
Using these in a report
In the SiteSnag app, starting to type a defect title in the camera brings up these entries. Picking one fills in the description, severity, trade and reference, and you can edit the wording or add your own defects to the library. Every snag then goes into the branded PDF report with its photos and a numbered pin on the floor plan.
For a room-by-room walk-round, use the new build snagging checklist, or go back to all defect categories.
Other categories
Previous: Doors & joinery (38). Next: Floors (16).
- Decoration (20)
- Walls & ceilings (19)
- Doors & joinery (38)
- Floors (16)
- Tiling (12)
- Kitchen (42)
- Bathroom (29)
- Plumbing (17)
- Heating (15)
- Electrical (28)
- External (33)
- General (9)
- Ventilation (6)
- Insulation & damp (10)
- Roofing (18)
- Drainage (8)
- Garage (5)
- Fire safety (17)
- Accessibility (8)
- Commercial fit-out (10)
- Mechanical & electrical (11)
- Lifts & doors (5)
- Car park & external works (7)
- Signage & security (6)
- Fitted furniture (7)
- Stairs (6)
- Structure (8)
- Timber & pests (8)
- Communal areas (6)