Insulation & damp defects in new builds
Damp and insulation problems show up as condensation, staining or mould, often in corners and around window reveals. Some of the causes, such as a bridged damp-proof course or high ground against a wall, can only be seen from outside.
Updated 19 October 2026
SiteSnag’s library has 10 entries under insulation & damp. They’re listed below with the most serious first. Each one gives the wording an inspector would put in a report and the trade that would fix it, and 6 carry a reference to the standard or guidance they relate to. The references help you look up the relevant section and aren’t a statement that a particular home does or doesn’t comply.
All 10 entries
Rising damp signs
MajorTide marks or salts at low level suggest rising damp. Investigate DPC.
- Trade
- Builder
- Reference
- Approved Document C
DPC bridged
MajorDamp-proof course bridged by ground, paving or render. Lower levels or cut back.
- Trade
- Builder
- Reference
- Approved Document C
Penetrating damp
MajorDamp staining from external defect. Trace source and repair.
- Trade
- Builder
- Reference
- Approved Document C
Cavity wall insulation concerns
MajorSigns of damp or failed cavity wall insulation. Specialist inspection.
- Trade
- Specialist
- Reference
- None listed
Loft insulation missing / disturbed
ModerateLoft insulation incomplete or disturbed. Lay to full depth.
- Trade
- Builder
- Reference
- Approved Document L
Condensation at reveals / cold bridging
ModerateCondensation or mould at window reveals indicating cold bridging. Investigate and rectify.
- Trade
- Builder
- Reference
- Approved Document L
Black mould on walls / ceilings
ModerateMould on wall or ceiling, usually from condensation. Treat and improve ventilation.
- Trade
- Builder
- Reference
- None listed
Damp from defective gutter / downpipe
ModerateDamp patch below a leaking gutter or downpipe. Repair rainwater goods and dry out.
- Trade
- Roofer
- Reference
- None listed
Ground level too high against wall
ModerateExternal ground or paving within 150 mm of DPC. Lower levels.
- Trade
- Groundworker
- Reference
- NHBC Standards 6.1
Condensation on windows
MinorHeavy condensation forming on glazing. Improve ventilation and heating.
- Trade
- Builder
- Reference
- None listed
Using these in a report
In the SiteSnag app, starting to type a defect title in the camera brings up these entries. Picking one fills in the description, severity, trade and reference, and you can edit the wording or add your own defects to the library. Every snag then goes into the branded PDF report with its photos and a numbered pin on the floor plan.
For a room-by-room walk-round, use the new build snagging checklist, or go back to all defect categories.
Other categories
Previous: Ventilation (6). Next: Roofing (18).
- Decoration (20)
- Walls & ceilings (19)
- Doors & joinery (38)
- Windows & glazing (22)
- Floors (16)
- Tiling (12)
- Kitchen (42)
- Bathroom (29)
- Plumbing (17)
- Heating (15)
- Electrical (28)
- External (33)
- General (9)
- Ventilation (6)
- Roofing (18)
- Drainage (8)
- Garage (5)
- Fire safety (17)
- Accessibility (8)
- Commercial fit-out (10)
- Mechanical & electrical (11)
- Lifts & doors (5)
- Car park & external works (7)
- Signage & security (6)
- Fitted furniture (7)
- Stairs (6)
- Structure (8)
- Timber & pests (8)
- Communal areas (6)